What the SRVO-291 alarm means
The temperature inside the intelligent power module exceeded its limit - the power stage itself is running too hot. Our engineers run into this alarm every week on FANUC R-30iA / R-30iB / R-30iB Plus controllers, and a single on-site inspection usually identifies the problem.
Most common causes
- Failed amplifier fan or dust-blocked heatsink
- High ambient temperature plus heavy duty cycle
- Degraded thermal interface inside an aging amplifier
Step-by-step field fix
- Same cooling checks as SRVO-253
- Monitor which axis alarms - single-axis overheating often means that amp is degrading
- Plan amplifier replacement if cleaning and cooling do not cure it
How we diagnose amplifier/hardware alarms on site
FANUC srvo-291 belongs to the amplifier & hardware family. On FANUC srvo-291 the failing stage is alpha-i / beta-i servo amplifiers with PSM supply modules and SVM servo modules (SPM where spindles fit) on the R-30iB Plus / R-30iB Mate Plus / R-30iA - the amplifier and drive hardware itself plus its periphery: boards, fuses, cooling, supply, connectors and self-test. We start reading FANUC srvo-291 at the iPendant ALARM screen (SRVO / MOTN / SYST / INTF prefixes) together with the amplifier's 7-segment status code.
The chain involved in FANUC srvo-291 runs: control-side signal -> amplifier board (drive and sense circuits) -> fuses and supply -> cooling -> motor-side output.
When FANUC srvo-291 fires, clear the external causes first - Many hardware alarms are not hardware at all but external conditions: a packed filter causing over-temperature, a missing phase causing undervoltage, a loose connector causing a communication drop. Our order clears the externals first - clean, replace the mat, measure supply, re-seat terminals - near-zero cost and a high hit rate. Only when externals are gone do we judge boards or power stage. It also keeps the quotation honest: we do not sell parts we have not earned.
Field notes on this page cover FANUC srvo-291 (IPM Overheat); written by the Henghuan repair team, updated 2026-10-01.
Stalled on the diagnosis? Let an engineer help remotely
Give us the alarm code, robot model and the action at the moment of the alarm, and our engineers can give you a quick read — phone or video remote diagnosis is free.
Get a Free Remote Diagnosis See Repair Services
Hotline: +86-20-39029800 · WhatsApp: +86-188-1886-2860
Related Amplifier & Hardware alarms
SRVO-057 — FSSB Disconnect SRVO-068 — DTERR - Data Transmission Error SRVO-069 — CRCERR - CRC Error SRVO-071 — SPHAL - Soft Phase Alarm SRVO-072 — PMAL - Pulse Coder Phase Alarm SRVO-073 — CMAL - Pulse Coder Count ErrorFrequently asked questions
QWhat does the FANUC srvo-291 alarm mean?
The temperature inside the intelligent power module exceeded its limit - the power stage itself is running too hot. Our engineers run into this alarm every week on FANUC R-30iA / R-30iB / R-30iB Plus controllers, and a single on-site inspection usually identifies the problem. FANUC srvo-291 sits in the amplifier & hardware family; on our work orders the highest-frequency trigger for this code is "Failed amplifier fan or dust-blocked heatsink".
QCan I clear a FANUC srvo-291 alarm myself?
Whether FANUC srvo-291 clears on its own depends on the outcome of "Same cooling checks as SRVO-253". Finish the flow with "Plan amplifier replacement if cleaning and cooling do not cure it" to confirm FANUC srvo-291 - do not skip it. If that step is clean, the second most frequent cause on FANUC srvo-291 is "High ambient temperature plus heavy duty cycle". Two attempts and still there means stop: FANUC srvo-291 involves live boards and power devices, and running FANUC srvo-291 on can turn a repairable fault into a replacement.
QFor hardware alarms like FANUC srvo-291, does it always mean an expensive part swap?
The commonest causes we see on FANUC srvo-291 are "Failed amplifier fan or dust-blocked heatsink, High ambient temperature plus heavy duty cycle, Degraded thermal interface inside an aging amplifier", so we stock the van against those. For FANUC srvo-291 specifically, we carry fuses, filter mats, common connectors and terminals; boards are stocked by type or go through the repair channel. For FANUC srvo-291, on hardware alarms we inspect before quoting - we do not open with replace the power stage. Before we roll, tell us what FANUC srvo-291 shows on the iPendant ALARM screen (SRVO / MOTN / SYST / INTF prefixes) together with the amplifier's 7-segment status code and what the machine was doing - phone or video triage is free.
This page on FANUC srvo-291 is based on the field experience of the Henghuan Robotics repair team. Alarm explanations are our own summary for troubleshooting reference and may differ across controller and software versions — if unsure, verify against FANUC documentation or reach out to us. Henghuan is an independent service provider with no affiliation or endorsement by FANUC.