What the Er.400 alarm means
DC bus voltage exceeded the upper threshold, usually from regenerative energy the braking resistor could not absorb or a high incoming supply. This is a routine repair in our workshop for INOVANCE IRCB500 / IRCB501 + SV660 servo systems, and we normally pin it down during the first site check.
Most common causes
- Braking resistor open, disconnected, or undersized
- Incoming AC voltage above rating
- Deceleration too aggressive for the inertia
- Voltage spikes from neighboring heavy loads
Step-by-step field fix
- Measure the braking resistor and inspect its wiring — start here
- Measure incoming supply voltage
- Soften deceleration ramps in the failing move
- Set the regenerative parameter to match the installed resistor
- Add line conditioning if plant power is spiky
How we diagnose drive alarms on site
INOVANCE er-400 belongs to the drive & power stage family. On INOVANCE er-400 the failing stage is Inovance servos (SV660N class), same family as the robot controller on the Inovance robot controllers (IRCB series and kin) - the fault sits on the energy chain: mains input, rectification, DC bus, braking resistor, inverter power devices and the drive board. We start reading INOVANCE er-400 at the pendant alarm screen (ER.xxx / 0x9xxx segments) and the servo panel Er code.
The chain involved in INOVANCE er-400 runs: three-phase mains -> rectifier -> DC bus (bus capacitors) -> brake chopper / braking resistor -> inverter (IGBT) -> motor.
When INOVANCE er-400 fires, the site usually reports Braking resistor open, disconnected, or undersized first, but the real cause is often cooling: More than half of power-stage alarms are not a dead device but a device cooked by failed cooling. A stopped cabinet fan, a packed filter mat or a dusted air duct keeps IGBT junction temperature high: intermittent over-temperature first, hard fault days later. On these alarms we open the power module and look for cracked thermal paste and felted dust in the duct, then measure phase-to-phase output and insulation to frame. Swapping the module without cleaning the duct just buys the same failure again.
Field notes on this page cover INOVANCE er-400 (Main Circuit Overvoltage); written by the Henghuan repair team, updated 2026-10-01.
Not sure? Don't force it — contact an engineer
Give us the alarm code, robot model and the action at the moment of the alarm, and our engineers can give you a quick read — phone or video remote diagnosis is free.
Get a Free Remote Diagnosis See Repair Services
Hotline: +86-20-39029800 · WhatsApp: +86-188-1886-2860
Related Drive & Power Stage alarms
Er.201 — Hardware Overcurrent Er.210 — Motor Overload Er.410 — Main Circuit Undervoltage Er.610 — Drive Overload (I2t) Er.920 — Regenerative OverloadFrequently asked questions
QWhat does the INOVANCE er-400 alarm mean?
DC bus voltage exceeded the upper threshold, usually from regenerative energy the braking resistor could not absorb or a high incoming supply. This is a routine repair in our workshop for INOVANCE IRCB500 / IRCB501 + SV660 servo systems, and we normally pin it down during the first site check. INOVANCE er-400 sits in the drive & power stage family; on our work orders the highest-frequency trigger for this code is "Braking resistor open, disconnected, or undersized".
QCan I clear a INOVANCE er-400 alarm myself?
Whether INOVANCE er-400 clears on its own depends on the outcome of "Measure the braking resistor and inspect its wiring — start here". Finish the flow with "Add line conditioning if plant power is spiky" to confirm INOVANCE er-400 - do not skip it. If that step is clean, the second most frequent cause on INOVANCE er-400 is "Incoming AC voltage above rating". If INOVANCE er-400 returns after two clears, or the checks point at Braking resistor open, disconnected, or undersized, stop the cell and call a professional robot repair engineer.
QFor drive/power alarms like INOVANCE er-400, what spares do you bring on site?
The commonest causes we see on INOVANCE er-400 are "Braking resistor open, disconnected, or undersized, Incoming AC voltage above rating, Deceleration too aggressive for the inertia", so we stock the van against those. For INOVANCE er-400 specifically, we stock the van along the energy chain: braking resistors, bus capacitors, input fuses, drive-board supply parts and the common power modules for the brand. For INOVANCE er-400, drive alarms usually stop the whole line, so they sit at the front of our dispatch queue. Before we roll, tell us what INOVANCE er-400 shows on the pendant alarm screen (ER.xxx / 0x9xxx segments) and the servo panel Er code and what the machine was doing - phone or video triage is free.
The content on INOVANCE er-400 was written by Henghuan Robotics service engineers from hands-on repair experience. Alarm descriptions are our own reference summary and may differ by controller or software version — defer to INOVANCE documentation, or contact us to confirm. Henghuan is an independent service provider with no affiliation or endorsement by INOVANCE.