What the A.02 alarm means
One or more servo parameters stored in the ESTUN drive are outside the valid range or inconsistent with each other; the drive refuses servo-on until the parameters are corrected. Our engineers run into this alarm every week on ESTUN ERC / ED3L controller + ESTUN servo controllers, and a single on-site inspection usually identifies the problem.
Most common causes
- Parameters edited by hand and saved with out-of-range values
- Drive firmware updated but old parameter file reloaded
- Parameter corruption after a power dip during write
- Wrong motor model code entered for the connected motor
Step-by-step field fix
- Note the sub-code shown with A.02 to identify which parameter is invalid
- Compare the parameter against the ESTUN parameter manual default table
- Re-enter the correct value, save, and power-cycle the drive
- If many parameters are invalid, restore from a known-good backup file
- Verify the motor model code matches the nameplate before servo-on
How we diagnose drive alarms on site
ESTUN a-02 belongs to the drive & power stage family. On ESTUN a-02 the failing stage is matched servo drives (in-house / Inovance-class servos) on the ESTUN robot controllers (motion-control-platform based) - the fault sits on the energy chain: mains input, rectification, DC bus, braking resistor, inverter power devices and the drive board. We start reading ESTUN a-02 at the pendant alarm list (A.xxx / E.xxx segments) and the servo panel display code.
The chain involved in ESTUN a-02 runs: three-phase mains -> rectifier -> DC bus (bus capacitors) -> brake chopper / braking resistor -> inverter (IGBT) -> motor.
Bottom line up front: Parameters edited by hand and saved with out-of-range values is the first suspect for ESTUN a-02, but read it along the energy chain: Any link on this chain dropping voltage shows up at the end as a drive alarm, so order matters. We measure the mains first: more than 3% phase imbalance is enough to sag the bus under load, and plenty of bus over/under-voltage alarms are actually a grid problem wearing a robot costume. Mains fine, then the bus capacitors - bulged cases, weeping electrolyte or a lifted vent mean replacement; capacitance down 20% or more cannot hold the bus during braking. Last, the braking resistor: healthy values sit in the tens of ohms depending on rating, and an open or drifted resistor trips regenerative overvoltage directly.
Field notes on this page cover ESTUN a-02 (Parameter Setting Error); written by the Henghuan repair team, updated 2026-10-01.
No luck? Hand it to the team that fixes this daily
Give us the alarm code, robot model and the action at the moment of the alarm, and our engineers can give you a quick read — phone or video remote diagnosis is free.
Get a Free Remote Diagnosis See Repair Services
Hotline: +86-20-39029800 · WhatsApp: +86-188-1886-2860
Related Drive & Power Stage alarms
A.10 — Overcurrent A.30 — Regeneration Error / Regenerative Overload A.40 — Main Circuit Overvoltage A.41 — Main Circuit Undervoltage A.71 — Overload — Instantaneous High Load A.72 — Overload — Continuous Over-torqueFrequently asked questions
QWhat does the ESTUN a-02 alarm mean?
One or more servo parameters stored in the ESTUN drive are outside the valid range or inconsistent with each other; the drive refuses servo-on until the parameters are corrected. Our engineers run into this alarm every week on ESTUN ERC / ED3L controller + ESTUN servo controllers, and a single on-site inspection usually identifies the problem. ESTUN a-02 sits in the drive & power stage family; on our work orders the highest-frequency trigger for this code is "Parameters edited by hand and saved with out-of-range values".
QCan I clear a ESTUN a-02 alarm myself?
Whether ESTUN a-02 clears on its own depends on the outcome of "Note the sub-code shown with A.02 to identify which parameter is invalid". Finish the flow with "Verify the motor model code matches the nameplate before servo-on" to confirm ESTUN a-02 - do not skip it. If that step is clean, the second most frequent cause on ESTUN a-02 is "Drive firmware updated but old parameter file reloaded". When ESTUN a-02 keeps coming back it is not a one-off trigger - especially if Verify the motor model code matches the nameplate before servo-on is where you get stuck. Do not keep producing through ESTUN a-02.
QFor drive/power alarms like ESTUN a-02, what spares do you bring on site?
The commonest causes we see on ESTUN a-02 are "Parameters edited by hand and saved with out-of-range values, Drive firmware updated but old parameter file reloaded, Parameter corruption after a power dip during write", so we stock the van against those. For ESTUN a-02 specifically, we stock the van along the energy chain: braking resistors, bus capacitors, input fuses, drive-board supply parts and the common power modules for the brand. For ESTUN a-02, drive alarms usually stop the whole line, so they sit at the front of our dispatch queue. Before we roll, tell us what ESTUN a-02 shows on the pendant alarm list (A.xxx / E.xxx segments) and the servo panel display code and what the machine was doing - phone or video triage is free.
This page on ESTUN a-02 was written by the Henghuan Robotics repair team from field service experience. Alarm descriptions are our own summary for troubleshooting reference and may vary by controller and software version — when in doubt, check your ESTUN documentation or contact us. Henghuan is an independent service provider, not affiliated with or endorsed by ESTUN.