What the SRVO-047 alarm means
The control power supply voltage inside the amplifier dropped below the lower limit. This is one of the faults our repair team handles most often — the cause is usually identifiable within the first on-site inspection.
Most common causes
- Incoming 3-phase voltage low or phase loss
- Control power supply unit (CPS) degraded
- Transformer tap mismatch
- Poor connections on power input terminals
Step-by-step field fix
- Measure incoming 3-phase voltage under load
- Check all phases present and terminals tight
- Verify transformer tap matches local supply
- If input is good, test/replace the control power supply
Still stuck? Get an engineer on the phone — right now
Tell us the alarm code, the robot model and what was happening when the alarm came up. Our engineers run these diagnostics every day, and remote diagnosis by phone or video call is free.
Get a Free Remote Diagnosis See Repair Services
Hotline: +86-20-39029800 · WhatsApp: +86-188-1886-2860
Related Servo & Drive alarms
SRVO-021 — SRDY Off (Group / Axis) SRVO-023 — Stop Error Excess (Group / Axis) SRVO-024 — Move Error Excess (Group / Axis) SRVO-043 — DCAL Alarm - Discharge Alarm SRVO-044 — HVAL Alarm - High Voltage SRVO-045 — HCAL Alarm - High CurrentFrequently asked questions
QWhat does the FANUC SRVO-047 alarm mean?
The control power supply voltage inside the amplifier dropped below the lower limit. In field practice it belongs to the servo & drive family of faults.
QCan I clear a FANUC SRVO-047 alarm myself?
Sometimes. Follow the step-by-step checks on this page — start with the first cause listed, which is what we find most often in the field. If the alarm returns after two attempts, or the fault involves power/safety circuits, stop and call a qualified robot service engineer.
QHow fast can a Henghuan engineer help?
On-site response in the Pearl River Delta within 30 minutes to 3 hours, across mainland China in 1–3 business days, and worldwide within 2–5 business days. Remote diagnosis by phone/WhatsApp/video is available immediately.
Written by the Henghuan Robotics repair team from field service experience. Alarm descriptions are our own summary for troubleshooting reference and may vary by controller version — when in doubt, check your FANUC documentation or contact us. Henghuan is an independent service provider, not affiliated with or endorsed by FANUC.