What the 38103 alarm means
The controller lost communication with the serial measurement board (SMB) in the robot base — position feedback from the absolute encoders is unavailable. This fault ranks high in our ABB IRC5 / OmniCore (RobotWare) service records, and the first site inspection usually finds the source.
Most common causes
- SMB cable disconnected or damaged at the X2 connector or robot base
- Broken SMB board
- Resolver/cable damage
- Corroded or loose connector pins
Step-by-step field fix
- Power down and reseat the SMB cable at both the cabinet X2 and the robot base
- Inspect the cable for damage along the dress pack
- Measure continuity and check connector pins for corrosion
- Swap in a known-good SMB board if the cable checks out
- After repair, update revolution counters and recalibrate if needed
How we diagnose communication alarms on site
ABB 38103 belongs to the communication family. On ABB 38103 the failing stage is IRC5 / OmniCore - the data link: fieldbus, Ethernet, cabinet-to-body communication and external device interfaces. We start reading ABB 38103 at the FlexPendant event log and system diagnostics, with the cabinet status LEDs.
The chain involved in ABB 38103 runs: physical layer (cable / connector / shield) -> link layer (protocol / baud / node ID) -> application layer (data mapping / handshakes).
If SMB cable disconnected or damaged at the X2 connector or robot base on ABB 38103 is intermittent and a reboot buys a while: Intermittent drops that a reboot clears for a while are usually interference. Power cables sharing a trunk with communication cables, poor common grounding between drives and robot, or a shield landed at both ends forming a ground loop all produce exactly this. We check spacing between communication and power runs, single- versus double-ended shield landing, and the cabinet earth-bar connections. The fix is often re-routing and re-grounding - no hardware - but it needs a coordinated stop.
Field notes on this page cover ABB 38103 (Communication with SMB Interrupted); written by the Henghuan repair team, updated 2026-10-01.
No luck? Hand it to the team that fixes this daily
Tell us these three: alarm code, robot model, and the operating condition at the alarm. ABB 38103 is a diagnosis our engineers do daily, and phone/video remote diagnosis is free.
Get a Free Remote Diagnosis See Repair Services
Hotline: +86-20-39029800 · WhatsApp: +86-188-1886-2860
Related Communication alarms
10012 — Guard Stop (Protective Stop) State 10013 — Emergency Stop State 20032 — Revolution Counters Not Updated 50053 — Too Large Revolution Counter Difference 50056 — Joint Collision 50057 — Joint Not SynchronizedFrequently asked questions
QWhat does the ABB 38103 alarm mean?
The controller lost communication with the serial measurement board (SMB) in the robot base — position feedback from the absolute encoders is unavailable. This fault ranks high in our ABB IRC5 / OmniCore (RobotWare) service records, and the first site inspection usually finds the source. ABB 38103 sits in the communication family; on our work orders the highest-frequency trigger for this code is "SMB cable disconnected or damaged at the X2 connector or robot base".
QCan I clear a ABB 38103 alarm myself?
Whether ABB 38103 clears on its own depends on the outcome of "Power down and reseat the SMB cable at both the cabinet X2 and the robot base". Finish the flow with "After repair, update revolution counters and recalibrate if needed" to confirm ABB 38103 - do not skip it. If that step is clean, the second most frequent cause on ABB 38103 is "Broken SMB board". Do not chase takt through a repeating ABB 38103. Left alone, communication faults tend to graduate from repairable to must-replace.
QFor communication alarms like ABB 38103, how long does a site visit take?
The commonest causes we see on ABB 38103 are "SMB cable disconnected or damaged at the X2 connector or robot base, Broken SMB board, Resolver/cable damage", so we stock the van against those. For ABB 38103 specifically, we carry common bus cables, connectors, termination resistors and shield terminals. For ABB 38103, communication work is about tracing the physical link segment by segment; most cases close in one visit. Before we roll, tell us what ABB 38103 shows on the FlexPendant event log and system diagnostics, with the cabinet status LEDs and what the machine was doing - phone or video triage is free.
This page on ABB 38103 was written by the Henghuan Robotics repair team from field service experience. Alarm descriptions are our own summary for troubleshooting reference and may vary by controller and software version — when in doubt, check your ABB documentation or contact us. Henghuan is an independent service provider, not affiliated with or endorsed by ABB.